EverFocus eDR400 Instruction Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 112
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
EDSR PTZ setup.
Once the data cables are connected, the EDSR recorder is configured to communicate with PTZ camera or cameras.
Please Note: you need to determine what Protocol and Baud Rate is used for the cameras. (Note: All cameras connecting to the
same DVR MUST be on the same Protocol and Baud Rate.)
SETTINGS:
1.) Access the Setup menu by pressing [MENU]
on the front of the unit.
2.) Use the Jog Wheel to highlight the PTZ menu.
Press[ENTER]
3.) In PTZ SETTINGS sub-menu, use [ENTER]
to navigate between the options and the JOG
WHEEL to change the settings.
4.) Set PTZ ENABLE: to ON,
5.) Set the PTZ port to RS485
6.) *Set the PROTOCOL to that of the Cameras
(Pelco-D, Pelco-P, Everfocus, or VProtect)
7.) *Set the BAUD RATE to match that of the
cameras
8.) Under PTZ ADDRESS, enter the Address for
that camera on that specific channel. (Example:
Channel 2 has a camera with Address 1, then
for CH2: the value is change to 001, so it reads
[CH2: 001].)
9.) Press [ENTER] twice to exit out of the setup menus. Restart the system.
*Note: These settings MUST match all the cameras connected on the same circuit.