EverFocus ECOR960 16F2 User Manual Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 149
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
ECOR960 4F2 / 8F2 / 16F2
17
2.2.2 Alarm I / O
The DVR provides 4 alarm inputs and 1 alarm outputs. Please refer to the table below for PIN
assignment.
COM NC G G 4 3 G G 2 1
Alarm Out Alarm In
Figure 2-13
Alarm Input
No.
Description
1-4
ALM_IN1 ALM_IN4
G GND
Alarm Input Contacts
This DVR provides one alarm input per camera. All inputs are programmable N.O. (Normal
Open) or N.C. (Normal Closed). All settings are programmed in the ALARM / Event menu.
ALMIN
GND
ALMIN
GND
Alarm Input with N.O. contact in idle state Alarm Input with N.C. contact in idle state
Alarm Output Contacts
The relay output provides Normally Closed dry contacts.
Page view 25