Page view 17
NAV Series TCP/IP Standalone Network Access Controller
10
Figure 2-4
2.2.2.2ConnectingtotheMagneticLock
In the figure,V+ representsone pin of the external power supply; if a DC powersupply is
used, V+ is connected with the positive pole, and if an AC power supply is used, the two
pinscanbeoptionallyconnected.
Figure 2-5
Note:Themaximumoutputcurrentoftherelayonthecontrollerissmallerthan4A.Ifthe
currentofthedoorlockisoverthisvalue,therelaywillbeexpanded.
2.2.2.3ConnectingtotheDoorSensor
Thecontrollerprovidestheinterfaceofthedoorsensor.Thedoorsensorisconnectedwith
the No.13 extension wire on the back plate of the controller, and the ground terminal is
connectedwiththeNo.11extensionwire.
COM
N.C.
V-V+
10
12
V+ V-
N.O.
COM
12
14