EverFocus EDSR-1600 User Manual

Browse online or download User Manual for Digital Video Recorders (DVR) EverFocus EDSR-1600. EverFocus EDSR-1600 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTRUCTION MANUAL
EDSR-900
9 Channel Duplex Digital Video Recorder
V1.09
EDSR-1600
16 Channel Duplex Digital Video Recorder
Page view 0
1 2 3 4 5 6 ... 67 68

Summary of Contents

Page 1 - EDSR-1600

INSTRUCTION MANUALEDSR-9009 Channel Duplex Digital Video RecorderV1.09EDSR-160016 Channel Duplex Digital Video Recorder

Page 2 - Safety Precautions

System Connection53. System ConnectionThe installations described below should be made by qualified service personnel or system installers.Before Inst

Page 3

Front Panel Keypads4. Front Panel KeypadsSHUTTLE : In Playback mode, turn the shuttle ring to fastforward/rewind the picture (600X maximum).In Pause

Page 4 - Important Safeguards

LEDs: LEDs for HDD1, HDD2 , ALARM and LAN access (from left to right).IR Remote Controller receiver7Display: Press this key to switch ON/OFF for camer

Page 5 - Table of Contents

Operation8(1) Insert a HDD (IDE) for Video Storage (2) Connect cable for video/audio input and video/audio out, The detail connection is describe

Page 6 - Product Overview

MENU flow6. MENU FLOWCLOCK( See page 11 ): 2005/04/15 FRI: 13:01:02CLOCK SETTING MENUDATE TIME MENU LANGUAGE: ENGLISHVIDEO SYSTEM: NTSC

Page 7 - Specifications

CONTROL( See page 24)CONTROL SETTING MENU BAUD RATESTOP BIT PARITYDATA BITBAUD RATESTOP BITPARITYDATA BITRS232/RS485 ID : 9600 BPS: 1: NON

Page 8 - Back Panel Connections

MENU11In CLOCK/LANGUAGE SETTING MENU , we define:(1) DATE : Current date, format: YYYY/MM/DDYear: 2000 ~ 2099, Month: 01~ 12, Date: 01~31, Week: Sun

Page 9

MENU12This menu provides automatically switching to Daylight Saving Time and back to Normal Time.Standard start and end times in Middle Europe: Last S

Page 10 - System Connection

MENU6.3 TIMER SETTING MENU13Timer records can be defined for 16 individual start and end times.(1) WEEK: Select the week day for the timer to record o

Page 11 - Front Panel Keypads

MENU(1) CH (Channel): Input channels. 1~9 for EDSR-900, 1~16 for EDSR-1600.(2) OP (Operation): ON includes the camera in the sequence, OFF skips th

Page 12

Refer all work related to the installation of this product to qualified service personnel or system installers.Do not block the ventilation opening or

Page 13 - Operation

MENU156.5 TITLE SETTING MENUIn the TITLE SETTING MENU we define:The Title Setting Menu allows you to assign a title to each camera input.Title with up

Page 14 - MENU flow

6.6 COVERT SETTING MENUCOVERT SETTING MENUCH OP1 OFF2 OFF3 OFF4 OFF5 OFF6 OFF7 OFF8 OFF9 OFF10 OFF1

Page 15

In ALARM RECORDING MENU, we define (1) CH (Alarm input) : Select alarm input or RST for alarm reset input.(2) OP (OPERATION) : ON : Records when alar

Page 16 - 6.1 CLOCK SETTING MENU

MENU(1) CH (Channel): video input channel(2) OP (Operation): Default: OFFON: The device will respond recording when motion occurs.OFF: The device wil

Page 17 - 6.2 DAYLIGHT SAVING TIME

MENU(5) HIT 1-9/16 TO MANUAL EDIT:Use the number keys (1~9 for EDSR-900 / 1~16 for EDSR-1600) to select a camera for setting the detection areas.The s

Page 18 - 6.3 TIMER SETTING MENU

MENU20In NORMAL RECORDING MENU we define(1) NORMAL RECORD:SPEED : Choose the normal recording speed. Maximum 60 (NTSC) / 50 (PAL).QUALITY: Define the

Page 19 - 6.4 SEQUENCE SETTING MENU

MENU21(3) PRE-ALARM RECORD: (with Alarm In and Motion)Pre-alarm duration is depending on recording quality (about 8-15 seconds).OP (Operation): Select

Page 20 - 6.5 TITLE SETTING MENU

6.10 NETWORK SETTING MENUIP ADDRESSNET MASK ADDRESSGATEWAY ADDRESSMAC ADDRESSUSER-NAME PASSWORD LEVEL NETWORK SETTING M

Page 21 - 6.6 COVERT SETTING MENU

23MENUTurn the JOG dial clockwise or counter-clockwise to select the options.Press MENU key to return to Main Menu, press again to leave Set up Menu.M

Page 22 - 6.7 ALARM RECORD SETTING MENU

MENU(1) RS232 BAUD RATE: There are 6 different speeds that can be used to transmit instruction or information through the RS232 port on the device, 12

Page 23 - 6.8 MOTION SETTING MENU

The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance(servicing)instru

Page 24

In BUZZER SETTING MENU, we define the buzzer ON/OFF for following event:RECORD-IN, ALARM-IN, MOTION-IN, DISK FULL, VIDEO LOSS AND TIMER.Please selec

Page 25 - 6.9 RECORD SETTING MENU

MENU6.13 ARCHIVE SETTING MENU(1) PICTURE SIZE :Selects picture size for copying image to CF card:Big size:720x480 / 720x576 for NTSC / PAL.Small size:

Page 26

6.14 MATRIX SETTING MENU27CH DWELL EVENT1 07 SECS NONE2 07 SECS NONE3 07 SECS NONE4 07 SECS NONE5 07 SE

Page 27 - 6.10 NETWORK SETTING MENU

MENU6.15 DISK MENUDISK SETTING MENUDISK USAGE HDD-1 HDD-2SIZE (GB) 120 120RECORD POS *78,2% 0%PLAY POS *39,5% 0%DISK RENEW NO NOI

Page 28

MENU296.16 PTZ SETTING MENUThe EDSR600/900/1600 Recorder from FW 1.09 provides telemetry control over network. Local device telemetry control at the

Page 29 - 6.11 CONTROL SETTING MENU

MENU301 2 3 4 5 6 7 8 ONOFFONOFF 1 2 3 4 5 6 7 8 SW501 Example: Connection ED-2250 Dome to EDSR600/900/1600Control of EverFocus ED2250 speed

Page 30 - 6.12 BUZZER SETTING MENU

MENU31RS-232 - Connection ED2250 Dome

Page 31 - 6.13 ARCHIVE SETTING MENU

MENU326.17 SYSTEM SETTING MENU(1) PLAY WITH AUDIO: AUDIO-1, AUDIO-2ON/OFF: Playback with or without audio.(2) PLAY SPEED: Set the playback speed. Maxi

Page 32 - 6.14 MATRIX SETTING MENU

7.1 INSTANT RECORDINGPress REC key to start continuous recording with setting of “NORMAL RECORD”. The recording rate and recording quality are set in

Page 33 - 6.15 DISK MENU

Recording7.3 PERMANENT RECORDINGNo manual operation is required, the automatic permanent recording is defined and activated in the RECORD menu. 7.4 TI

Page 34 - 6.16 PTZ SETTING MENU

Important SafeguardsRead Instruction---All the safety and operating instructions should be read before the init is operatedRetain Instructions---The s

Page 35 - 1 2 3 4 5 6 7 8

8.1 NORMAL PLAYBACKPress the PLAY key to start playing back the stored video/audio from the last SEGMENT. (1) Playback(2) Fast Forward/Reverse Playba

Page 36

8.2 SEARCH PLAYBACKPress SEARCH key to enter the SEARCH MENU dialog.Search PlaybackSEARCH36SEGMENT SEARCH0001 A01 0002 M020003 M032005/04/24

Page 37 - 6.17 SYSTEM SETTING MENU

(2) Alarm List search playback37A01 : Alarm recording by Alarm-in 1. M03: Motion recording by camera 3. T : Timer recording.PL: automatic record resta

Page 38 - Recording

(3) Date/Time Search PlaybackDATE/TIME SEARCHYYYY/MM/DD HH:MM:SS HDD2003 /01 /01 21: 33: 26 1PRESS SEARCH TO START SEARCHPRESS MENU TO EXI

Page 39

DATA EXPORTInsert a Compact Flash card into the Compact Flash slot on the front panel of DVR.When inserting the Compact Flash card, make sure that ins

Page 40 - Playing Back

COPYPress COPY key and then the copy menu and instruction appears.The main monitor switches to full screen display with following OSD:40Press the PLAY

Page 41 - Search Playback

9.3 EXPORT EVENT LOG LISTDATA EXPORTThis function allows to export the event log list to CompactFlash – Card.The generated text file in in *.txt forma

Page 42

MONITOR VIEWS / OPERATION10. MONITOR VIEWS / OPERATION10.1. MAIN MONITORThe EDSR900/1600 digital recorders provide 1 main monitor and 5 matrix monit

Page 43

Press CALL to change settings for CALL / MATRIX monitors. The Main monitor shows following dialogue:MONITOR VIEWS / OPERATION10.2. CALL / MATRIX MONI

Page 44 - DATA EXPORT

RJ45 (RS-485) pin assignment11. REMOTE CONTROL11.1 RS-485 REMOTE CONTROLThe new standard EverFocus EDSR remote control protocol allows sophisticated i

Page 45

Table of Contents1. Product Overview…………………………………….………………..… ..… .. ... Page 11.1 Main features…………………………………………………………………...… ..……… 11.2 Spe

Page 46

REMOTE CONTROL / OPERATIONWiring diagram single EDSR controlWiring diagram multiple EDSR controlWiring diagram multiple keyboard controlRS485B /yellow

Page 47 - MONITOR VIEWS / OPERATION

IR REMOTE CONTROLLER / OPERATIONThe remote controller (RC-200, Figure 1) is an accessory to enhance the handy operations of the DVR. You can perform

Page 48

12. View From Internet/IntranetBasic Operations and Login Display:Before you start: Please make sure the service ports 0080, 1111, 2222, 3333, 4444, a

Page 49 - REMOTE CONTROL / OPERATION

Main ScreenAbove diagram is the main screen display.The icons on the lower corner of the screen are mainly for control and Configuration, those on the

Page 50

10. The system allows up to 3 ways playback video, by SEGMENT, ALARM LIST and DATE TIME.(Playback by SEGMENT LIST, click Refresh to show segment list

Page 51 - Figure 1

11. All available segments are shown in the list. Click to select and highlight. 12. Click to playback selected video segment.13. Press this icon to s

Page 52 - View From Internet/Intranet

MENU51PTZ-CONTROL WITH WEB BROWSER (from FW 1.09 only)If the checkbox "PTZ CONTROL" is activated in the Web’s applet of the EDSR600/900/1600

Page 53

The EDSR 900/1600 provides 3 levels with different user rights in operating, if password protection is activated in SYSTEM menu.USER RIGHTS:LEVEL 1: A

Page 54

Appendix-ALAN Functional SpecificationSpecifications:Network Interface: 10Mbits/s Ethernet (10Base T)LAN controller Chip:

Page 55

Appendix-B ? When Recording with 160GB HDD54Lower Low Basic StandardHighSuperior: 15 kB: 19 kB: 23 kB: 27 kB: 31 kB: 35 kB(Estimated with typical i

Page 56

1. Product OverviewThe EDSR-900 / EDSR1600 Duplex Digital Video Recorder (DVR) a full-featured DVR designed specifically for use in security industry.

Page 57 - 13. PASSWORD PROTECTION

? When Recording with 320GB HDDLower Low Basic StandardHighSuperior: 15 kB: 19 kB: 23 kB: 27 kB: 31 kB: 35 kBAppendix-B 55(Estimated with typical

Page 58 - Appendix-A

Appendix C: Serial Interface Specifications2. Transmission settingPIN # NAME PIN # NAME1 NOT CONNECTED 1 NOT CONNECTED2 TXD

Page 59 - Appendix-B

3. Remote Control ProtocolA computer or a terminal can be used to control the unit by sending the packet as following.571-1. Sample control code packe

Page 60

582-1. The format of message packet is as follows:Length Byte (Prefix: 0x86, 0x87, or 0x88 ... )Receiver ID high byteReceiver ID low byteOpcode Byt

Page 61

592-3. Receiver ID2-3. Receiver ID1). Individual receiver IDDecimal 14bit binary value Hbyte Lbyte Receiver ID (EDSR)0 0000000 0000000 00 00 ID = 01 0

Page 62 - 3. Remote Control Protocol

602-4. Opcode Byte & Data bytes2-4-1. OPcodeOPcode Data1 Function0x4B Keycode A remote key pressed0x4D command Matrix command 2-4-2.

Page 63

2-4-3. Matrix command (OPcode=0x4D)Data1 Matrix function0x00 Matrix monitor0 - ch01 spot 0x01 Matrix monitor0 - ch02 spot0x02 Matrix mo

Page 64

Appendix-D62Alarm I/O pin assignmentThe alarm connector, Figure 1, is used to provide one sensor alarm input for each camera input.For easy operation,

Page 65 - OPcode Data1 Function

EverFocus Electronics Corp.Head Office:12F, No.79 Sec. 1 Shin-Tai Wu Road,Hsi-Chih, Taipei, Taiwanwww.everfocus.com.twUSA Office:2445 Huntington Drive

Page 66 - 2-5. Checksum Byte

Specifications21.2 Specifications9 (EDSR900) / 16 (EDSR1600) camera inputs (BNC),1Vp-p/75ohm430mm (W) x 88mm (H) x 300 (D) DimensionAC100~240VPower So

Page 67 - Appendix-D

Back Panel Connections2. Back Panel Connections1ON/OFF: Main on/off switch.2 AC100~240V power socket. 3VIDEO IN: BNC-sockets for composite signal

Page 68 - EverFocus

410ALM-OUTPUT : Two-way contact relay alarm output. In normal condition, this N.C. contact shorted to ALM-COM. In alarm status, it is open between AL

Comments to this Manuals

No comments